VTSYIQI
VTSYIQI Rebar Corrosion Detector Digital Reinforcement Position Tester with Bar Diameter Φ6-50mm Potential Measurement Range ±1000mV Distance Of Test Point 0-1000mm Accuracy ±1mV 50000 Test Points
- Regular price
- $2,880.00

VTSYIQI Rebar Corrosion Detector Digital Reinforcement Position Tester with Bar Diameter Φ6-50mm Potential Measurement Range ±1000mV Distance Of Test Point 0-1000mm Accuracy ±1mV 50000 Test Points
About this item
Integrated functions of rebar position test,concrete cover test, rebar diameter test rebar scan and rebar corrosion degree test into one product.
Testing concrete cover thickness Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution.Estimation bar diameter Detection of Cable and Plumbing pipe Detection of steel corrosion extent.
Grid scanning mode and profile scanning mode. It can intuitively display the distribution diagram of steel bars, and scan it.
Easy to operate,have concise software interface,have powerful analytical processing,can obtain testing report directly.
Measured data is inputted to PC software from USB interface.
◆Feature◆
◆Integrated functions of rebar position test,concrete cover test, rebar diameter test rebar scan and rebar corrosion degree test into one product.
◆Product Usage◆
◆Testing concrete cover thickness Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution.Estimation bar diameter Detection of Cable and Plumbing pipe Detection of steel corrosion extent.
◆Specification of Rebar Locator◆
◆Bar diameter application range(mm):φ6-φ50
◆Maximum permissible error of Bar diameter:≤土1
◆Cover thickness measuring range:
The first measuring range (mm):6- 90
The second measuring range (mm):7-180
◆The maximum error of cover thickness:
The first measuring range (mm):
6- 59 ≤土1;
60-69 ≤土2;
70 -90 ≤士4
The second measuring range (mm):
7-79 ≤土1;
80- 119 ≤土2;
120- 180 ≤士4
◆Work temperature °C: -10- +40
◆Relative humidity RH: <90%
◆Power supply:Alkaline cell X 6(Batteries are not included in the package)
◆Specification of Rebar Corrosion System◆
◆Measuring Potential:±1999mv
◆Test accuracy:±1mV
◆Measuring Space:1-99 cm (adjustable)
◆Ambient Temperature:-10°C~+40°C
◆Environment Requirement:to avoid direct exposure to the sun for a long time.
◆Relative Humidity:<90%RH
◆Electromagnetic Interference: no strong alternating electromagnetic field
◆Distance of test point:0-1000mm
◆Available capacity:50000 test point 5000 test areas