VTSYIQI Multi Parameter Water Quality Meter Water Quality Tester with Conductivity Solutions Range -1999.9 to 1999.9 mV Range 0.00 to 20.00 MΩ Auto-read Function for Measuring pH mV ORP Ion Concentration Conductivity TDS Salinity Resistivity DO

About this item

Automatic temperature compensation ensures accurate readings over the entire range.

Auto-read function senses and locks the measurement endpoint.

Calibration due alarm reminds the user to calibrate the meter regularly.

Setup menu allows setting the number of calibration points, stability criteria, temperature unit, date and time, etc.

USB communication interface enables easy data transfer and timed interval readings.

pH Mode:

Multiparameter water quality meter is equipped with a large backlit LCD display.

1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.

Automatic electrode diagnosis shows the pH slope and zero offset.

ORP Mode:

1 point offset calibration allows adjusting the displayed value to a known standard.

Relative and absolute millivolt modes ensure the reliable ORP measurements.

Ion Concentration Mode:
2 to 5 points calibration, including the selection of 8 concentration points.

Automatic electrode diagnosis shows the calibration points and slopes.

Direct ion concentration readout simplifies the measurement process.

Selectable concentration units (ppm, mg/L, mol/L) and ionic valency.

Conductivity/TDS/Salinity/Resistivity Modes:

1 to 5 points calibration with automatic recognition for conductivity standards.

Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes.

Dissolved Oxygen Mode:

1 or 2 points calibration using the air-saturated water or zero oxygen solution.

Salinity and barometric pressure compensations eliminate measurement errors.

Other Features:

Automatic temperature compensation ensures accurate readings over the entire range.

Auto-read function senses and locks the measurement endpoint.

Calibration due alarm reminds user to calibrate the meter regularly.

Setup menu allows setting the number of calibration points, stability criteria, temperature unit,  date and time, auto-power off, etc.

Reset function automatically restores all settings to the factory defaults.

Expanded memory stores or recalls up to 500 data sets.

USB communication interface enables easy data transfer and timed interval readings.

pH

Range: -2.000 to 20.000 pH

Resolution:  0.001 / 0.01 / 0.1 pH, selectable

Accuracy: ±0.002 pH

Calibration: 1 to 5 points

pH Buffer Options:USA / NIST / DIN / 2 custom buffers

ORP

Range: -1999.9 to 1999.9 mV

Resolution: 0.1 / 1 mV, selectable

Accuracy: ±0.2 mV

Calibration: 1 point

Measurement Modes: Relative / Absolute mV

Ion Concentration

Range: 0.00 to 19999 (depending on the range of ISE)

Resolution: 0.001, 0.01, 0.1, 1, automatic

Accuracy: ±0.5% F.S. (monovalent), ±1% F.S. (divalent)

Calibration: 2 to 5 points

Calibration Solutions:  0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000

Measurement Units: ppm, mg/L, mol/L, mmol/L
Conductivity

Range: 0 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm

Resolution: 0.001, 0.01, 0.1, 1, automatic

Accuracy: ±0.5% F.S.

Calibration: 1 to 5 points

Calibration Solutions: 10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS

Temperature Coefficient: 0.0 to 10.0%/°C

Pure Water Compensation: Yes

Reference Temperature: 20 / 25°C

Cell Constant:  K=0.1 / 1 / 10 / Custom

TDS

Range: 0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt

Resolution: 0.01, 0.1, 1, automatic

Accuracy: ±1% F.S.

TDS Conversion Factor: 0.1 to 1.0 (default 0.5)

Salinity

Range: 0.00 to 80.00 ppt / 0.00 to 42.00 psu

Resolution: 0.01

Accuracy: ±1% F.S.

Resistivity

Range: 0.00 to 20.00 MΩ

Resolution: 0.01

Accuracy: ±1% F.S.

Dissolved Oxygen

Range: 0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation

Resolution: 0.01 / 0.1, selectable

Accuracy: ±0.2 mg/L / ±2.0 %

Calibration: 1 or 2 points

Pressure Correction: 60.0 to 112.5 kPa / 450 to 850 mmHg, manual

Salinity Correction: 0.0 to 50.0 g/L, manual

Temperature

Range: 0 to 105°C / 32 to 221°F

Resolution: 0.1°C/°F

Accuracy: ±0.5°C / ±0.9°F

Calibration: 1 point

Calibration Range: Reading ±10°C/°F

Other Specifications

Temperature Compensation: 0 to 100°C / 32 to 212°F, manual or automatic

Hold Function: Manual / Auto-read measurement endpoint

Stability Criteria: Low / High

Calibration Due Alarm: 1 to 31 days or off

Memory: Stores up to 500 data sets

Output: USB communication interface

Connector: BNC, 6-pin mini-DIN, 3.5 mm jack socket

Display: Custom LCD (125 × 100 mm)

Power Supply: 5V DC power adapter

Environmental Conditions: 0 to 50°C / 32 to 122°F, relative humidity < 80%

Dimensions: 210 × 188 × 60 mm

Weight: 1.5 kg

Meter Includes

P11 glass pH electrode

K10 conductivity electrode

DO100 dissolved oxygen electrode

TP-10K temperature probe

pH 4.01, 7.00, 10.01 buffer reagents

Conductivity standard solutions 84 µS/cm, 1413 µS/cm, 12.88 mS/cm

DO electrolyte solution

DO membrane cap

USB cable

What level of performance can I expect from 4K Color Drive?
This tv comes equipped with a 4k color drive, which allows the tv to accurately reproduce a wider spectrum of colors. you’ll experience an exceptionally vibrant, pristine image that makes each scene more lifelike.

You may also like

    Complementary products

      • Item Title

        Describe the item, make announcements or welcome customers to your store.

      • Item Title

        Describe the item, make announcements or welcome customers to your store.

      • Item Title

        Describe the item, make announcements or welcome customers to your store.