VTSYIQI
VTSYIQI Multiparameter Water Quality Meter Water Quality Meter with Calibration Fluid ORP Range -1999.9 to 1999.9 mV USB Communication Interface for Measuring pH ORP Ion Concentration Conductivity TDS Aalinity Resistivity Dissolved Oxygen
- Regular price
- $1,335.00

VTSYIQI Multiparameter Water Quality Meter Water Quality Meter with Calibration Fluid ORP Range -1999.9 to 1999.9 mV USB Communication Interface for Measuring pH ORP Ion Concentration Conductivity TDS Aalinity Resistivity Dissolved Oxygen
About this item:
Multiparameter water quality meter contains 8 measurement modes, the meter is suitable for measuring pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and dissolved oxygen
Automatic temperature compensation ensures accurate readings over the entire range.
Auto-Read function senses and locks the measurement endpoint.
Calibration due alarm prompts user to calibrate the meter regularly.
USB communication interface is easy to transfer data to PC.
pH Mode:
Portable multiparameter water quality meter is equipped with a backlit LCD display.
1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
Automatic electrode diagnosis shows the pH slope and zero offset.
ORP Mode
1 point offset calibration allows adjusting the displayed value to a known standard.
Relative and absolute millivolt modes ensure the reliable ORP measurements.
Ion Concentration Mode:
2 to 5 points calibration, including the selection of 8 concentration points.
Automatic electrode diagnosis shows the calibration points and slopes.
Direct ion concentration readout simplifies the measurement process.
Selectable concentration units (ppm, mg/L, mol/L) and ionic valency.
Conductivity/TDS/Salinity/Resistivity Modes:
1 to 5 points calibration with automatic recognition for conductivity standards.
Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
1 or 2 points calibration using the air-saturated water or zero oxygen solution.
Salinity and barometric pressure compensations eliminate measurement errors.
Other Features:
Automatic temperature compensation ensures accurate readings over the entire range.
Auto-read function senses and locks the measurement endpoint.
Calibration due alarm reminds user to calibrate the meter regularly.
Auto-power off effectively conserves battery life.
Setup menu allows setting the number of calibration points, stability criteria, temperature unit, date and time, etc.
Reset function automatically restores all settings to the factory defaults.
Expanded memory stores or recalls up to 500 data sets.
USB communication interface enables easy data transfer to a PC.
Multi-mode power scheme (batteries, power adapter, USB port) ensures the smooth operation of the meter
pH
Range: -2.000 to 20.000 pH
Resolution: 0.001 / 0.01 / 0.1 pH, selectable
Accuracy: ±0.002 pH
Calibration: 1 to 5 points
pH Buffer Options: USA / NIST / DIN / 2 custom buffers
ORP
Range: -1999.9 to 1999.9 mV
Resolution: 0.1 / 1 mV, selectable
Accuracy: ±0.2 mV
Calibration: 1 point
Measurement Modes: Relative / Absolute mV
Ion Concentration
Range: 0.00 to 19999 (depending on the range of ISE)
Resolution: 0.001, 0.01, 0.1, 1, automatic
Accuracy: ±0.5% F.S. (monovalent), ±1% F.S. (divalent)
Calibration: 2 to 5 points
Calibration Solutions: 0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000
Measurement Units: ppm, mg/L, mol/L, mmol/L
Conductivity
Range: 0 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Resolution: 0.001, 0.01, 0.1, 1, automatic
Accuracy: ±0.5% F.S.
Calibration: 1 to 5 point
Calibration Solutions: 10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS
Temperature Coefficient: 0.0 to 10.0%/°C
Pure Water Compensation: Yes
Reference Temperature: 20 / 25°C
Cell Constant: K=0.1 / 1 / 10 / Custom
TDS
Range: 0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt
Resolution: 0.01, 0.1, 1, automatic
Accuracy: ±1% F.S.
TDS Conversion Factor: 0.1 to 1.0 (default 0.5)
Salinity
Range: 0.00 to 80.00 ppt / 0.00 to 42.00 psu
Resolution: 0.01
Accuracy: ±1% F.S.
Resistivity
Range: 0.00 to 20.00 MΩ
Resolution: 0.01
Accuracy: ±1% F.S.
Dissolved Oxygen
Range: 0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation
Resolution: 0.01 / 0.1, selectable
Accuracy: ±0.2 mg/L / ±2.0 %
Calibration: 1 or 2 points
Pressure Correction: 60.0 to 112.5 kPa / 450 to 850 mmHg, manual
Salinity Correctio: 0.0 to 50.0 g/L, manual
Temperature
Range: 0 to 105°C / 32 to 221°F
Resolution: 0.1°C/°F
Accuracy: ±0.5°C / ±0.9°F
Calibration: 1 point
Calibration Range: Reading ±10°C/°F
Other Specifications
Temperature Compensation: 0 to 100°C / 32 to 212°F, manual or automatic
Hold Function: Manual / Auto-read measurement endpoint
Stability Criteria: Low / High
Calibration Due Alarm: 1 to 31 days or off
Auto-Power Off: 10 / 20 / 30 minutes after last key pressed
Memory: Stores up to 500 data sets
Output: USB communication interface
Connector: BNC, 6-pin mini-DIN, 3.5 mm jack socket
Display: Custom LCD (80 × 60 mm)
Power Supply: 3 × 1.5V AA batteries or 5V DC power adapter
Battery Life: Approximately 150 hours without backlight
Environmental Conditions: 0 to 50°C / 32 to 122°F, relative humidity < 80%
Dimensions: 170 × 85 × 30 mm
Weight: 300 g
Meter Includes:
P11 glass pH electrode
K10 conductivity electrode
DO100 dissolved oxygen electrode
TP-10K temperature probe
pH 4.01, 7.00, 10.01 buffer reagents
Conductivity standard solutions 84 µS/cm, 1413 µS/cm, 12.88 mS/cm
DO electrolyte solution
DO membrane cap
Electrode clip
Carrying case