OVERVIEW

The VERG-4000 series AC/DC withstand voltage tester adopts a 5-inch color LCD display screen and is equipped with mainstream high-performance ARM processor, which is stable in performance and easy to operate. The standard 2U chassis has a compact structure that does not take up space and is suitable for supporting equipment development. Fully isolated design and floating ground output enhance anti-interference ability!

The VERG-4000 is equipped with a Controller (PLC), RS232C interface, and network port, making it convenient for data communication and remote control with a PC, meeting the requirements of automated testing and improving production efficiency.

FEATURES

it can provide 5kVAC/20mA withstand voltage, 6kVDC/10mA withstand voltage, and insulation resistance testing.

Three in one AC withstand voltage, DC withstand voltage, and insulation resistance testing

2U standard chassis

Floating test

Enhance anti-interference capability

It can independently conduct AC withstand voltage testing, DC withstand voltage testing, and insulation resistance testing, and can also perform multi item sequential testing through the project settings of the testing plan.

SPECIFICATIONS

Measurement Functions:AC/DC Withstanding Voltage & IR Insulation Resistance

Interface: RS232/Handler/LAN/USB

Arc Detection: 9 Levels (AC/DC)

Other Functions: LIST Edit;Discharge Function;5“ LCD

AC Withstand Voltage:

Rate Ouput: AC 5.000kV/20mA

Output Voltage: 0.050kV-5.000KV AC;Resolution: 1V

Voltage Accuracy: 2% of reading + 5 digits

Output Regulation: 2% of reading +5V

Output Frequency: 50Hz/60Hz

Measurement Current: 0.001mA-20.00mA;Resolution: 0.001 / 0.01

Current Accuracy: 2% of reading + 5 digits

Rising Time: 0.1s-999.9s

Testing Time: 0.2s-999.9s

Falling Time: 0.1s-999.9s

DC Withstand Voltage :

Rate Output: DC 6kV/10mA

Output Voltage: 0.050kV-6.000kV DC;Resolution: 1V

Voltage Accuracy: 2% of reading + 5 digits

Output Regulation: 2% of reading +5V

Current Measurement: 0.1μA-10.000mA

Current Accuracy: 2% of reading +5 digits

Rising Time: 0.1s-999.9s

Testing Time: 0.2s-999.9s

Falling Time: 0.1s-999.9s

Insulation Resistance:

Rate Output: DC 1kV/10GΩ

Output Voltage: 0.050kV-1.000kV DC;Resolution: 1V

Voltage Accuracy: 1% of reading + 2 digits

Measurement Range: 0.1MΩ-10GΩ

IR Accuracy: <500V:0.1MΩ-1GΩ, Accuracy:±(10% of reading +5 digits );1GΩ-10GΩ , For reference only, no accuracy requirement

≥ 500V:1MΩ-1GΩ, Accuracy:±(5% of reading +5 digits);1GΩ-10GΩ, Accuracy:±(10% of reading +5 digits)

Testing Time: 0.2s-999.9s

Power Supply 110VAC~220VAC 47Hz~63Hz 300VA

Dimension & Weight 270mm( W )x130mm( H )x450mm ( D );8kg

Accessories:High voltage test rod;Withstand voltage test line; RS232 Communication