{"product_id":"vtsyiqi-digital-ground-resistance-meter-earth-resistance-meter-soil-resistivity-tester-with-soil-resistivity-range-0-9000kωm-resistance-0-01ω-30-00kω-2-pole-3-pole-4-pole-500-groups-storage-iec61010-1","title":"VTSYIQI Digital Ground Resistance Meter Earth Resistance Meter Soil Resistivity Tester with Soil Resistivity Range 0-9000kΩm Resistance 0.01Ω-30.00KΩ 2‑Pole 3-Pole 4-Pole 500 Groups Storage IEC61010-1","description":"\u003cp class=\"a-size-base-plus a-text-bold\"\u003e\u003cstrong\u003eAbout this item\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eFunction Two, three, four-wire measure grounding resistance, soil resistivity; Ground voltage, AC voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eAmbient temperature and humidity 23℃±5℃，below 75%rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eRange Grounding resistance: 0.00Ω to 30.00kΩ Soil resistivity: 0.00Ωm～9999kΩm Ground voltage: 0.00V to 600.0V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eMeasurement Method Precision 4-wire, 3-wire measurement, simple 2-wire grounding resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eMeasuring Methods Grounding resistance: rated current change method Soil resistivity: four-pole method Ground voltage: average rectification (S-ES interface)\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"celwidget aplus-module 3p-module-b aplus-standard\" data-csa-c-id=\"p4po16-7c3i5b-dgtc6a-2l2zpl\" data-cel-widget=\"aplus-3p-module-b\"\u003e\n\u003cdiv class=\"aplus-module-wrapper aplus-3p-fixed-width\"\u003e\n\u003cp class=\"a-spacing-base\"\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eFour Wire Ground Resistance Tester Meter Specification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eFunction : Two, three, four-wire measure grounding resistance, soil resistivity; Ground voltage, AC voltage\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eAmbient temperature and humidity : 23℃±5℃，below 75%rh\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003ePower Supply : DC 9V 6-section LR14 Dry Battery Standby for more than 100 hours\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eInterference voltage : ＜20V(should be avoided)\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eInterference current : \u0026lt;2A (should be avoided)\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eMeasure R electrode spacing : a\u0026gt;5d\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eMeasured electrode spacing : a\u0026gt;20h\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eAuxiliary Earth Resistance : Reference Conditions \u0026lt;100Ω, Operating Conditions \u0026lt;5kΩ\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eRange : Grounding resistance: 0.00Ω to 30.00kΩ\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e: Soil resistivity: 0.00Ωm～9999kΩm\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e: Ground voltage: 0.00V to 600.0V\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"celwidget aplus-module launchpad-brand-description-left aplus-standard\" data-csa-c-id=\"ydeiyt-4wa0g6-ss6kmd-40dz4h\" data-cel-widget=\"aplus-launchpad-brand-description-left\"\u003e\n\u003cdiv class=\"a-section launchpad-module launchpad-module-brand-description-left\"\u003e\n\u003cdiv class=\"a-section launchpad-text-left-justify\"\u003e\n\u003cp\u003eFour-Wire Grounding Resistance Meter Tester Measurement Method : Precision 4-wire, 3-wire measurement, simple 2-wire grounding resistance\u003c\/p\u003e\n\u003cp\u003e4-Terminal Ground Resistance and Soil Resistivity Tester Digital Insulation MeterMeasuring Methods : Grounding resistance: rated current change method\u003c\/p\u003e\n\u003cp\u003e: Soil resistivity: four-pole method\u003c\/p\u003e\n\u003cp\u003e: Ground voltage: average rectification (S-ES interface)\u003c\/p\u003e\n\u003cp\u003eTest Frequency : 128Hz\u003c\/p\u003e\n\u003cp\u003eShort-circuit Test Current : AC \u0026gt;20mA (sine wave)\u003c\/p\u003e\n\u003cp\u003eOpen Circuit Test Voltage : AC 28V max\u003c\/p\u003e\n\u003cp\u003eElectrode Spacing Range : can be set from 1m to 100m\u003c\/p\u003e\n\u003cp\u003eChange Gear : Grounding resistance: fully automatic shifting from 0.00Ω to 30.00kΩ\u003c\/p\u003e\n\u003cp\u003e: Soil resistivity: 0.00 Ωm～9000kΩm automatic shifting\u003c\/p\u003e\n\u003cp\u003eBacklight : Gray screen backlight, suitable for dim places\u003c\/p\u003e\n\u003cp\u003eDisplay Mode : 4-digital super-large LCD display, blue screen backlight\u003c\/p\u003e\n\u003cp\u003eMeasuring Indicator : During measurement, LED flash\u003c\/p\u003e\n\u003cp\u003eLCD Frame Dimension : 111mm×65mm\u003c\/p\u003e\n\u003cp\u003eLCD display area : 108mm×65mm\u003c\/p\u003e\n\u003cp\u003eDimension : L×W×H: 240mm×188mm×85mm\u003c\/p\u003e\n\u003cp\u003eStandard Test Wire : 4 wires: each for red 20m, black 20m, yellow 10m, and green 10m\u003c\/p\u003e\n\u003cp\u003eSimple Test Wire : 2 wires: each for yellow 1.5m and green 1.5m\u003c\/p\u003e\n\u003cp\u003eAuxiliary Earthing Rod : 4 PCS\u003c\/p\u003e\n\u003cp\u003eMeasuring Rate : Voltage to ground: about 3 times\/second\u003c\/p\u003e\n\u003cp\u003e: Earth resistance, soil resistivity: about 7 seconds\/time\u003c\/p\u003e\n\u003cp\u003eCircuit Voltage : below AC 600V(The ground voltage measurement function cannot be used to measure commercial power)\u003c\/p\u003e\n\u003cp\u003eData Storage : 500 sets, “MEM” icon storage indicator, flash display “FULL” icon to indicate storage is full\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"celwidget aplus-module launchpad-brand-description-left aplus-standard\" data-csa-c-id=\"84bmy0-n9e8vx-lhdk3r-772yvk\" data-cel-widget=\"aplus-launchpad-brand-description-left\"\u003e\n\u003cdiv class=\"a-section launchpad-module launchpad-module-brand-description-left\"\u003e\n\u003cdiv class=\"a-section launchpad-text-left-justify\"\u003e\n\u003cp\u003eData Read : Data read function: “MR” icon display\u003c\/p\u003e\n\u003cp\u003eOverflow Display : Exceeding measuring range overflow function: “OL” icon display\u003c\/p\u003e\n\u003cp\u003eAlarm Function : Alarm when the measured value exceeds the alarm setting value\u003c\/p\u003e\n\u003cp\u003eBattery Voltage : Low battery voltage symbol display\u003c\/p\u003e\n\u003cp\u003eAutomatic Shut-down : \"APO\" instruction, automatically shut down after 15 minutes of power on\u003c\/p\u003e\n\u003cp\u003ePower Consumption : Standby: About 40mA (backlight off)\u003c\/p\u003e\n\u003cp\u003e: Turn on and backlight on: about 43mA\u003c\/p\u003e\n\u003cp\u003e: Measurement: about 75mA (backlight off)\u003c\/p\u003e\n\u003cp\u003eWeight : Tester：1230g (including battery)\u003c\/p\u003e\n\u003cp\u003e: Testing Wires：1300g\u003c\/p\u003e\n\u003cp\u003e: Auxiliary earthing rod：720g(4PCS)\u003c\/p\u003e\n\u003cp\u003eWorking Temperature \u0026amp; Humidity : -10℃～40℃；below 80%rh\u003c\/p\u003e\n\u003cp\u003eStorage temperature \u0026amp; humidity : -20℃～60℃；below 70%rh\u003c\/p\u003e\n\u003cp\u003eOverload Protection : Measuring earth ground resistance: between each interfaces of H-E、S-ES, AC 280V\/3 seconds\u003c\/p\u003e\n\u003cp\u003eInsulation Resistance : Over 20MΩ(between circuit and enclosure it is 500V)\u003c\/p\u003e\n\u003cp\u003eWithstanding Voltage : AC 3700V\/rms (Between circuit and enclosure)\u003c\/p\u003e\n\u003cp\u003eElectromagnetic Features : IEC61326(EMC)\u003c\/p\u003e\n\u003cp\u003eProtection Type : IEC61010-1 (CAT III 300V, CAT IV 150V, Pollution Degree 2);\u003c\/p\u003e\n\u003cp\u003e: IEC61010-031;\u003c\/p\u003e\n\u003cp\u003e: IEC61557-1 (grounding resistance);\u003c\/p\u003e\n\u003cp\u003e: IEC61557-5 (soil resistivity);\u003c\/p\u003e\n\u003cp\u003e: JJG 366-2004\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"VTSYIQI","offers":[{"title":"Default Title","offer_id":47743645515997,"sku":"FR3010E-ZHENGNENG-LUCKY-0","price":325.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/1749\/1165\/files\/7_438509ef-7c77-4aac-8b61-ef6a22f088bc.jpg?v=1775617369","url":"https:\/\/www.vtsyiqi.net\/products\/vtsyiqi-digital-ground-resistance-meter-earth-resistance-meter-soil-resistivity-tester-with-soil-resistivity-range-0-9000k%cf%89m-resistance-0-01%cf%89-30-00k%cf%89-2-pole-3-pole-4-pole-500-groups-storage-iec61010-1","provider":"VTSYIQI","version":"1.0","type":"link"}