{"product_id":"vtsyiqi-underground-wire-and-cable-locators-underground-pipe-and-cable-locator-utility-pipeline-detector-with-pipeline-measurement-depth-0-20m-transmitter-frequencies-accuracy-5-to-10-4-3-lcd-color-touch-screen","title":"VTSYIQI Underground Wire and Cable Locators Underground Pipe and Cable Locator Utility Pipeline Detector with Pipeline Measurement Depth 0-20m Transmitter Frequencies Accuracy ± 5% to -10% 4.3 LCD Color Touch Screen","description":"\u003cp\u003e\u003cstrong\u003eFeature:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eIntelligent pipeline detector, also known as underground utility cable locator, cable path instrument, is a path detection instrument with strong comprehensive performance. It has pipeline path detection, cable identification, fault search and other functions. The instrument is composed of transmitter, transmitting current clamp, receiver, receiving flexible current clamp, connecting test line, A-fault locator frame (optional), etc.Intelligent pipeline detector can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables under trenchless excavation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eCable identification is designed for power cable engineers and cable workers to solve the technical problems of cable identification. Can be used to identify live cables and blackout cables. The user accurately identifies one of the target cables from multiple cables through the instrument to avoid missawing non target cables. When cable identification, 20 cables can be pre-rated at the transmitting end, and then received and identified at the far end, which greatly saves the calibration operation time of engineering personnel and improves the work efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eSignal transmitter: used for pipeline path detection and cable identification.The device can add identification signals to the target cable through direct connection output, caliper coupling, induction method, and so on. There are 13 different pulse signals of 250Hz, 577Hz, 640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 33 kHz, 66 kHz, 82 kHz, and 197 kHz.The maximum signal output power is 15W, and 6 levels are adjustable, adapting to different application environments, making pipeline detection and cable identification more accurate and reliable.Instrument built-in large function rate can be charged with lithium battery, automatic impedance matching, automatic protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eReceiver：For pipeline path detection and cable identification. Built-in shielding 3D antennas can effectively identify 13 different pulse-coded current signals of 250Hz, 577Hz, 640Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 33 kHz, 66 kHz, 82 kHz and 197 kHz generated by the transmitter, and 50Hz and 60Hz power frequency signals and center frequencies of 33 kHz and 82 kHz.Use a 4.3-inch capacitive touch LCD screen, real-time dynamic display of 360 comprehensive pipeline path indication, depth, current and relative pipeline position.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eFlexible current clamp：For the cable identification. The current clamp is a Roche coil, with excellent transient tracking ability, and can quickly identify the pulse width frequency signals generated by the transmitter. It is suitable for thick cables or irregularly shaped conductors.The inner diameter of the jaw is about 200mm, can clamp Φ200mm below the cable, do not need to disconnect the measured line, non-contact measurement, safe and fast.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eSpecial note: When power outage cable identification: no access to the live cable. Live cable identification is only applicable to three-core armored cable. When identifying, the transmitting clamp and the receiving clamp should not be mixed, and the direction of the input signal should be consistent.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eCharacteristics:1.Multiple detection modes: classical positioning mode, wire cruise mode, signal distortion measurement mode;2.Classic positioning mode: compass, direction and signal amplitude display, visually display the left and right direction of the pipeline。3.Lead cruise mode: 360 omnidirectional pipeline path indication, continuous display of depth, current, and pipeline relative position. The interface is simple and intuitive, and it can be operated without experience4.Signal distortion measurement mode: the peak and trough wave form should be displayed at the same time. In the field without distortion, the peak and valley value position should be consistent\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eIntroduction:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e1.Multiple detection modes: classical positioning mode, wire cruise mode, signal distortion measurement mode;\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e2.Classic positioning mode: compass, direction and signal amplitude display, visually display the left and right direction of the pipeline\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e3.Lead cruise mode: 360 omnidirectional pipeline path indication, continuous display of depth, current, and pipeline relative position. The interface is simple and intuitive, and it can be operated without experience\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e4.Signal distortion measurement mode: the peak and trough wave form should be displayed at the same time. In the field without distortion, the peak and valley value position should be consistent, and the field shape should be symmetrical relative to the centrol line.\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e5.Current direction determination (partial frequency), can be calibration current direction, eliminate adjacent line interference, to prevent tracking errors.\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e6.Full digital high-precision sampling processing: stable and reliable, ultra-high sensitivity, extremely narrow reception frequency band, strong anti-interference ability, can fully inhibit the power frequency and harmonic interference of adjacent running cables and pipelines.\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e7.Multiple detection frequencies: 13 active detection frequencies and 2 passive detection frequencies.\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e8.Transmitter a variety of signal output: direct output, caliper coupling, induction method.\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e9.Transmitter digital amplifier power output, automatic impedance matching, automatic protection.\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eReceiver specifications:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eFunction:Utility detector(cable position tracking, direction display, depth measurement, current measurement), cable identification, A-frame fault detection (optional function)\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003ePower:8.4V large capacity rechargeable lithium battery\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eInput mode:Built-in receiving coil, flexible caliper, A-frame (optional function)\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eReceive frequency:Active detection frequency:250Hz、577Hz、640Hz、1.28kHz、2.56kHz、3.20kHz、4.09kHz、8.19kHz、10.2kHz、33kHz、66kHz、82kHz、197kHz\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003ePower frequency passive detection frequency：50Hz、60Hz\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eRF passive detection frequency band: the central frequency is divided into33kHz、66kHz、82kHz、197kHz\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eUtility detector modes:Wide peak method, narrow peak method, sound valley method\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eUtility detector display modes:Classic positioning mode, wire cruise mode, signal distortion measurement mode\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eUtility detection Scope of detection:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eDirect connection method: generally can reach the cable length of 0~20 kilometers, mainly determined by the grounding resistance, cable resistance and cable buried depth Coupling method: generally can reach the length of the cable 0~10 kilometers, mainly determined by the grounding resistance, cable resistance and cable buried depth Induction method: suitable for cables with buried depth less than 2m\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eDepth and current:Display the cable depth and current value in real time\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eMeasurement depth:0-20m\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eDeep precision:Flat position precision accuracy: Central axis position of the target cable or pipeline:± 5% (buried depth in 0-3m) -10% (buried depth in 3m-20m)\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003ePositive and wrong prompt: Excluding the interference of adjacent cables, in the measurement of adjacent cables, the measurement of the adjacent cables can be distinguished according to the different signal strength and the measured current phase of the adjacent cables. In the process of tracking the cables, the phase dial and pointer can be observed to distinguish the measured cables and the adjacent cables\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eSound instructions:FM tone with signal intensity\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eCapacity of resisting disturbance:Very narrow receiving frequency band and unique digital processing method can fully suppress the power frequency and harmonic interference of adjacent operating cables and pipelines\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eInterference distance:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eWhen using the coupling method and the induction method, the transmitter will produce interference in close distance. The distance of interference is related to the transmitting power and frequency. The greater the power, the higher the frequency, the stronger the interference.The minimum distance of the receiver free from the transmitter interference often needs to be determined by test:\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eUtility detection: 5m away, 20m away as no interference\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eCable identification: the coupling method beyond 2~5m can be confirmed as no interference\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e\u003cspan class=\"a-text-bold\"\u003eCable identification:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eIdentification mode: flexible caliper intelligent identification;\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eNumber of calibrable cables: 1~20;\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eCalibration value: the current percentage of the received signal and the transmitted signal between 75% and 135% of the calibration value is one of the conditions for successful identification;\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eDirectionality: the transmitter clamp, receiver clamp must be in the same direction as the loading signal, which is one of the conditions for successful identification\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eDirect connection method: can identify the signal with a circuit resistance of 0 Ω ~ 8 kΩ (generally, the length of the cable can reach 0~20 km, mainly determined by the grounding resistance and cable resistance)\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eCoupling method: can identify the signal with circuit resistance of 0 Ω ~ 1 kΩ; (generally the cable length is 0~6 km, mainly determined by the grounding resistance and cable resistance)\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eDisplay:4.3 LCD color screen LCD (highlight screen), visible in the sun\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eTouchscreen:Yes\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eSize:350mm(length)×155mm(width)×700mm(high)\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eWeight:Around 2kg\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eConnection interface:Type-C USB Interface, air socket\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eCoil inner diameter:φ200mm(A larger caliber can be customized as needed)\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eWorking temperature and humidity:-10℃～40℃；below 80%Rh\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eStore temperature and humidity:-10℃~50℃；≤95％RH, No knot dew\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eWithstand voltage:AC2000V\/rms(Before the front and rear ends of the shell)\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eSuitable for safety regulations:IEC61010-1 CAT Ⅲ 600V，IEC61010-031，IEC61326，Pollution grade 2\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e\u003cstrong\u003eReceiver specifications：\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"celwidget aplus-module launchpad-brand-description-left aplus-standard\" data-cel-widget=\"aplus-launchpad-brand-description-left\" data-csa-c-id=\"mzt85n-uhgf0a-fy366m-cq3ilu\"\u003e\n\u003cdiv class=\"a-section launchpad-module launchpad-module-brand-description-left\"\u003e\n\u003cdiv class=\"a-section launchpad-text-left-justify\"\u003e\n\u003cp\u003eFunction ： Utility detector(cable position tracking, direction display, depth measurement, current measurement), cable identification, A-frame fault detection (optional function)\u003c\/p\u003e\n\u003cp\u003ePower ： 8.4V large capacity rechargeable lithium battery\u003c\/p\u003e\n\u003cp\u003eInput mode ： Built-in receiving coil, flexible caliper, A-frame (optional function)\u003c\/p\u003e\n\u003cp\u003eReceive frequency ：\u003c\/p\u003e\n\u003cp\u003eActive detection frequency:250Hz、577Hz、640Hz、1.28kHz、2.56kHz、3.20kHz、4.09kHz、8.19kHz、10.2kHz、33kHz、66kHz、82kHz、197kHz\u003c\/p\u003e\n\u003cp\u003ePower frequency passive detection frequency：50Hz、60Hz\u003c\/p\u003e\n\u003cp\u003eRF passive detection frequency band: the central frequency is divided into33kHz、66kHz、82kHz、197kHz\u003c\/p\u003e\n\u003cp\u003eUtility detector modes ： Wide peak method, narrow peak method, sound valley method\u003c\/p\u003e\n\u003cp\u003eUtility detector display modes ： Classic positioning mode, wire cruise mode, signal distortion measurement mode\u003c\/p\u003e\n\u003cp\u003eUtility detection ： Direct connection method: generally can reach the cable length of 0~20 kilometers, mainly determined by the grounding resistance, cable resistance and cable buried depth\u003c\/p\u003e\n\u003cp\u003eScope of detection ：\u003c\/p\u003e\n\u003cp\u003eCoupling method: generally can reach the length of the cable 0~10 kilometers, mainly determined by the grounding resistance, cable resistance and cable buried depth\u003c\/p\u003e\n\u003cp\u003eInduction method: suitable for cables with buried depth less than 2m\u003c\/p\u003e\n\u003cp\u003eDepth and current ： Display the cable depth and current value in real time\u003c\/p\u003e\n\u003cp\u003emeasurement depth ： 0-20m\u003c\/p\u003e\n\u003cp\u003eDeep precision ：\u003c\/p\u003e\n\u003cp\u003eFlat position precision accuracy: Central axis position of the target cable or pipeline:\u003c\/p\u003e\n\u003cp\u003e± 5% (buried depth in 0-3m) -10% (buried depth in 3m-20m)\u003c\/p\u003e\n\u003cp\u003ePositive and wrong prompt ： Excluding the interference of adjacent cables, in the measurement of adjacent cables, the measurement of the adjacent cables can be distinguished according to the different signal strength and the measured current phase of the adjacent cables. In the process of tracking the cables, the phase dial and pointer can be observed to distinguish the measured cables and the adjacent cables\u003c\/p\u003e\n\u003cp\u003eSound instructions ： FM tone with signal intensity\u003c\/p\u003e\n\u003cp\u003eCapacity of resisting disturbance ： Very narrow receiving frequency band and unique digital processing method can fully suppress the power frequency and harmonic interference of adjacent operating cables and pipelines\u003c\/p\u003e\n\u003cp\u003eInterference distance ： When using the coupling method and the induction method, the transmitter will produce interference in close distance. The distance of interference is related to the transmitting power and frequency. The greater the power, the higher the frequency, the stronger the interference.The minimum distance of the receiver free from the transmitter interference often needs to be determined by test:\u003c\/p\u003e\n\u003cp\u003eUtility detection: 5m away, 20m away as no interference\u003c\/p\u003e\n\u003cp\u003eCable identification: the coupling method beyond 2~5m can be confirmed as no interference\u003c\/p\u003e\n\u003cp\u003eCable identification ： Identification mode: flexible caliper intelligent identification;\u003c\/p\u003e\n\u003cp\u003eNumber of calibrable cables: 1~20;\u003c\/p\u003e\n\u003cp\u003eCalibration value: the current percentage of the received signal and the transmitted signal between 75% and 135% of the calibration value is one of the conditions for successful identification;\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"celwidget aplus-module launchpad-brand-description-left aplus-standard\" data-cel-widget=\"aplus-launchpad-brand-description-left\" data-csa-c-id=\"imzqz4-wdfnli-1io7to-pcn0wm\"\u003e\n\u003cdiv class=\"a-section launchpad-module launchpad-module-brand-description-left\"\u003e\n\u003cdiv class=\"a-section launchpad-text-left-justify\"\u003e\n\u003cp\u003eDirectionality: the transmitter clamp, receiver clamp must be in the same direction as the loading signal, which is one of the conditions for successful identification\u003c\/p\u003e\n\u003cp\u003eCable identification ： Direct connection method: can identify the signal with a circuit resistance of 0 Ω ~ 8 kΩ (generally, the length of the cable can reach 0~20 km, mainly determined by the grounding resistance and cable resistance)\u003c\/p\u003e\n\u003cp\u003eRange of detection ： Coupling method: can identify the signal with circuit resistance of 0 Ω ~ 1 kΩ; (generally the cable length is 0~6 km, mainly determined by the grounding resistance and cable resistance)\u003c\/p\u003e\n\u003cp\u003eDisplay ： 4.3 LCD color screen LCD (highlight screen), visible in the sun\u003c\/p\u003e\n\u003cp\u003eTouchscreen ： Yes\u003c\/p\u003e\n\u003cp\u003eSize ： 350mm(length)×155mm(width)×700mm(high)\u003c\/p\u003e\n\u003cp\u003eWeight ： Around 2kg\u003c\/p\u003e\n\u003cp\u003eConnection interface ： Type-C USB Interface, air socket\u003c\/p\u003e\n\u003cp\u003eCoil inner diameter ： φ200mm(A larger caliber can be customized as needed)\u003c\/p\u003e\n\u003cp\u003eWorking temperature and humidity ： -10℃～40℃；below 80%Rh\u003c\/p\u003e\n\u003cp\u003eStore temperature and humidity ： -10℃~50℃；≤95％RH, No knot dew\u003c\/p\u003e\n\u003cp\u003eWithstand voltage ： AC2000V\/rms(Before the front and rear ends of the shell)\u003c\/p\u003e\n\u003cp\u003eSuitable for safety regulations ： IEC61010-1 CAT Ⅲ 600V，IEC61010-031，IEC61326，Pollution grade 2\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"VTSYIQI","offers":[{"title":"Default Title","offer_id":46807113269469,"sku":"ES7080-ZHNEGNENG-LUCKY-23","price":4032.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/1749\/1165\/files\/12_263eb7a3-6656-463e-9249-d900ec8ae46a.jpg?v=1758597757","url":"https:\/\/www.vtsyiqi.net\/products\/vtsyiqi-underground-wire-and-cable-locators-underground-pipe-and-cable-locator-utility-pipeline-detector-with-pipeline-measurement-depth-0-20m-transmitter-frequencies-accuracy-5-to-10-4-3-lcd-color-touch-screen","provider":"VTSYIQI","version":"1.0","type":"link"}